beautypg.com

IAI America XSEL-S User Manual

Page 451

background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

443

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

A4B Monitoring-record count

specification error

The specified number of records for monitoring data query

is invalid.

A4C Monitoring-operation special

command register busy error

The driver special command ACK generated a timeout

during monitoring operation.

A4E Parameter register busy error at

issuance of slave command

The driver special command ACK generated a timeout at

issuance of a slave command.

A4F Software reset refusal error during

operation

Software reset (SIO) is prohibited during operation

(program is running, servo is in use, etc.).

A50 Drive-source recovery request

refusal error

The drive-source cutoff factor (error, deadman switch,

safety gate, emergency stop, etc.) has not been removed.

A51 Operation-pause reset request

refusal error

The all-operation-pause factor (drive-source cutoff,

operation-pause signal, deadman switch, safety gate,

emergency stop, etc.) has not been removed.

A53 Refusal error due to servo ON

A processing not permitted during servo ON was attempted.

A54 Refusal error due to unsupported

function

The function is not supported.

A55 Refusal error due to exclusive

manufacturer function

A processing not opened to users other than the

manufacturer was attempted.

A56 Refusal error due to invalid data

The data is invalid.

A57 Program start duplication error

An attempt was made to start a program currently running.

A58 BCD error warning

The BCD value being read may be invalid, or the value

being written (variable 99) may be a negative value, among

other reasons.

A59 IN/OUT command port flag error

warning

The number of I/O ports (flags) may have exceeded 32,

among other reasons. Check the I/O port (flag)

specifications.

A5B Character-string � value

conversion error warning

The specified number of converting characters is invalid or

characters that cannot be converted to value are included.

A5C Copying-character count error

warning with SCPY command

The specified number of copying characters is invalid.

A5D SCIF open error in non-AUTO

mode

The channel was opened in a non-AUTO mode. In the

MANU mode, the PC/TP connection must be forcibly

disconnected before opening the serial channel opened to

the user. Exercise caution.

A5E I/O-port/flag count specification

error

The specified number of I/O ports/flags is invalid.

A5F Fieldbus error (LERROR-ON)

A LERROR-ON was detected.

A60 Fieldbus error (LERROR-BLINK)

A LERROR-BLINK was detected.

A61 Fieldbus error (HERROR-ON)

A HERROR-ON was detected.

A62 Fieldbus error (HERROR-BLINK)

A HERROR-BLINK was detected.

A63 Fieldbus not ready

Fieldbus ready cannot be confirmed.

A64 SCIF overrun error (SIO bridge)

Communication failure.

Check for noise, connected equipment and communication

setting.

A65 SCIF receive error (SIO bridge)

Communication failure.

Check for noise, shorted/disconnected communication

cable, connected equipment and communication setting.

M

es

sa

ge

le

ve

l e

rro

rs

A66 SCI overrun error (SIO bridge)

Communication failure.

Check for noise, circuit failure and slave card.

This manual is related to the following products: