beautypg.com

IAI America XSEL-S User Manual

Page 474

background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

466

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

E8D Parameter flash-ROM status error Data is not written to the flash ROM correctly or written in

an old, incompatible application version.

Cold-st

art

lev

el

errors

E8F

Fieldbus logic error

Invalid logic during Fieldbus initialization.



In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

F00 Shutdown error (hi_sysdwn ()

definition)

A shutdown error (hi_sysdwn () definition) was detected.

F03 to

F58

Shutdown error (OS call error)

A shutdown error (OS call error) was detected.

F60 System-down level error-call

procedure error

A system-down level error-call procedure error was

detected.

F61 Interpreter-task end task ID error

An interpreter-task end task ID error was detected.

F62 Abnormal standby power detection

error

Abnormal standby power was detected.

F63 Regenerative resistance

temperature error

A regenerative resistance temperature error was detected.

F64 AC-power overvoltage error

An AC-power overvoltage error was detected.

F65 Motor-power overvoltage error

A motor-power overvoltage error was detected.

F66 Servo control underrun error

A servo control underrun error was detected.

F67 FROM-write bus width error

A write operation other than 32-bit long word access was

detected while writing the flash ROM.

F68 FROM write protect error

Write operation to a write-protected flash ROM area

(FRMWE bit in DEVCTR = 1) was detected.

F69 Boot watchdog error

A FPGA boot watchdog was detected. The core program

may not be running properly.

F6A�

FA0

Undefined exception/interruption

error

An undefined exception/interruption occurred.

FB0 TMU0 interruption error

TMU0 interruption error was detected.

FB1 Application code SDRAM copy

error (Checksum)

The sum of 4 bytes does not match between the

corresponding sections after FROM � SDRAM program

copy.

FB2 Installed flash ROM type mismatch

(Application)

The flash ROM type anticipated in the software does not

match the flash ROM type actually installed. Check the

combination of software and hardware.

FB8 Undefined NMI error

An undefined NMI interruption occurred.

S

ys

te

m

-d

ow

n

le

ve

l e

rro

r

FF0 to

FFF

Shutdown error (hi_sysdwn()

definition)

A shutdown error (hi_sysdwn() definition) was detected.

This manual is related to the following products: