Chapter 6 Parameter
6.7 Other Parameters (All types)
384
Other Parameters (All types)
No.
Parameter name
Default
value
(reference)
Input range
Unit
Remarks
49 Panel 7-segment display
data type
0
0 to 9
0: Display controller status
1: Display motor current indicator
The current pattern of each axis is displayed
instead of “ready status” or “program run
number.”
“Minimum indicator-displayed axis number”
(far-right column) is specified by “Other
parameter No. 50.”
0 < Motor current to rating ratio (%) � 25
25 < Motor current to rating ratio (%) � 50
50 < Motor current to rating ratio (%) � 75
75 < Motor current to rating ratio (%) � 100
100 < Motor current to rating ratio (%) � 150
150 < Motor current to rating ratio (%) � 200
200 < Motor current to rating ratio (%)
2: Display user information number (U001 to
U999)
The user information number is displayed
instead of “ready status” or “program run
number” only when the user information number
is not “0.” “Global integer variable number for
specifying user information number” is specified
by “Other parameter No. 50.”
3: IA Net Station Number Display (IA00 to IA63)
IA Net Occupied Station Top Number is
displayed instead of “Ready Status Display” only
when IA Net is used.
50
Auxiliary specification for
panel 7-segment display
data type
0
-99999999 to
99999999
* Refer to the Remarks field for “Other parameter
No. 49.”
51 (For expansion)
0
52 Reserved by the system
(change is prohibited)
0
53 Fan Condition Monitoring
Setting 1
3FH
0H to
FFFFFFFFH
Bit 0: Fan
1 condition monitored
(0: Disable, 1: Enable)
Bit 1: Fan 2 condition monitored
(0: Disable, 1: Enable)
Bit 2: Fan 3 condition monitored
(0: Disable, 1: Enable)
Bit 3: Fan 4 condition monitored
(0: Disable, 1: Enable)
Bit 4: Fan 5 condition monitored
(0: Disable, 1: Enable)
Bit 5: Fan 6 condition monitored
(0: Disable, 1: Enable)