IAI America XSEL-S User Manual
Page 359
Chapter 6 Parameter
6.3.1 For XSEL-R/S
351
Axis-Specific Parameters (XSEL-R/S)
No.
Parameter name
Default value
(reference)
Input range
Unit
Remarks
87 Zone 1 MIN
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
88 Zone 1 Output No.
0
0 to 6999
Physical output port or Global Flag or
Extended Output Ports
(Output invalid when set to 0, invalid
when duplicated)
89 Zone 2 MAX
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
90 Zone 2 MIN
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
91 Zone 2 Output No.
0
0 to 6999
Physical output port or Global Flag or
Extended Output Ports
(Output invalid when set to 0, invalid
when duplicated)
92 Zone 3 MAX
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
93 Zone 3 MIN
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
94 Zone 3 Output No.
0
0 to 6999
Physical output port or Global Flag or
Extended Output Ports
(Output invalid when set to 0, invalid
when duplicated)
95 Zone 4 MAX
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
96 Zone 4 MIN
0
-99999999 to
99999999
0.001mm
Valid only when Max. > Min.
* Necessary to secure 3msec or more
for domain going-through time
97 Zone 4 Output No.
0
0 to 6999
Physical output port or Global Flag or
Extended Output Ports
(Output invalid when set to 0, invalid
when duplicated)
98 (For expansion)
0
99 (For expansion)
0
100 (For expansion)
0
101
Allowable Time for Excess
of Continuous Operational
Torque
0
0 to 300
s
Not to monitor excess time of
continuous operational torque when set
to 0
102 (For expansion)
0
103 (For expansion)
0