6.1 I/O Parameter (All types)

284

I/O Parameter (All types)

No.

Parameter name

Default

value

(reference)

Input

range

Unit

Remarks

38 Input function selection 008

1

0 to 5

0: General-purpose input,

1: Program number specified for program start

Note: The assignment changes depending on

the value set in “I/O parameter No. 30,

Input function selection 000.”

Note: The port number assigned to this function

can be changed using I/O parameter No.

291, “Port number assigned to input

function selection 008.”

39 Input function selection 009

1

0 to 5

0: General-purpose input,

1: Program number specified for program start

Note: The assignment changes depending on

the value set in “I/O parameter No. 30,

Input function selection 000.”

Note: The port number assigned to this function

can be changed using I/O parameter No.

292, “Port number assigned to input

function selection 009.”

40 Input function selection 010

1

0 to 5

0: General-purpose input,

1: Program number specified for program start

Note: The assignment changes depending on

the value set in “I/O parameter No. 30,

Input function selection 000.”

Note: The port number assigned to this function

can be changed using I/O parameter No.

293, “Port number assigned to input

function selection 010.”

41 Input function selection 011

1

0 to 5

0: General-purpose input,

1: Program number specified for program start

Note: The assignment changes depending on

the value set in “I/O parameter No. 30,

Input function selection 000.”

Note: The port number assigned to this function

can be changed using I/O parameter No.

294, “Port number assigned to input

function selection 011.”

42 Input function selection 012

1

0 to 5

0: General-purpose input,

1: Program number specified for program start

Note: The assignment changes depending on

the value set in “I/O parameter No. 30,

Input function selection 000.”

Note: The port number assigned to this function

can be changed using I/O parameter No.

295, “Port number assigned to input

function selection 012.”

43 Input function selection 013

1

0 to 5

0: General-purpose input

1: Program number specified for program start

2: Error reset (ON edge)

Note: The assignment changes depending on

the value set in “I/O parameter No. 30,

Input function selection 000.”

Note: The port number assigned to this function

can be changed using I/O parameter No.

296, “Port number assigned to input

function selection 013.”

This manual is related to the following products: