beautypg.com

IAI America XSEL-S User Manual

Page 138

background image

Chapter 2 Wiring

2.3.5 W

ring for extension I/O units

130

(1) Connection of IA Net

Connector

Connector

Model

Remarks

Cable side

FMC1.5/3-ST-3.5 (PHOENIX CONTACT)

Controller side

MCV1.5/3-G-3.5 (PHOENIX CONTACT)

Pin No.

Signal Name

Description

Applicable Wire Diameter

3

SLD

Shield Grounding

2

SB

Data sending B

1

SA

Data sending A

Cable dedicated for IAI products

� Dedicated cable (Model�CB-RS-IAN���)

���

indicates the cable length. (Example) 020 = 2m

Wiring Color Signal Name No.

Blue

SA

1

White

SB

2

AWG

22

-

SLD

(Drainage

wire)

3

(2) 24V Power Line Input

Connector

Connector

Model

Remarks

Cable side

FMC1.5/2-ST-3.5 (PHOENIX CONTACT)

Controller side

MCV1.5/2-G-3.5 (PHOENIX CONTACT)

Pin No.

Signal Name

Description

Applicable Wire Diameter

2

24V

Input power 24V (+) side

1

0V

Input power 0V (-) side�

0.08 to 1.25mm

2

(AWG28 to AWG16)

No. Signal Name Color

Wiring

1

SA

Blue

2

SB

White

3

SLD

(Drainage

wire)�

-

AWG

22

L=0.5m, 1 to 10m (m Unit)

L

Model Label

6.2mm

1

3

1

3