beautypg.com

IAI America XSEL-S User Manual

Page 310

background image

Chapter 6 Parameter

6.1 I/O Parameter (All types)

302

I/O Parameter (All types)

No.

Parameter name

Default

value

(reference)

Input

range

Unit

Remarks

286 Port number assigned to input

function selection 003

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 33, “Input function

selection 003.”

* If a negative value is set, the function will be

assigned to input port No. 3.

287 Port number assigned to input

function selection 004

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 34, “Input function

selection 004.”

* If a negative value is set, the function will be

assigned to input port No. 4.

288 Port number assigned to input

function selection 005

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 35, “Input function

selection 005.”

* If a negative value is set, the function will be

assigned to input port No. 5.

289 Port number assigned to input

function selection 006

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 36, “Input function

selection 006.”

* If a negative value is set, the function will be

assigned to input port No. 6.

290 Port number assigned to input

function selection 007

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 37, “Input function

selection 007.”

* If a negative value is set, the function will be

assigned to input port No. 7.

* If “Program number specified for program start”

has been specified for input function selection

007, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

(Related information: I/O parameter No. 30,

“Input function selection 000”)

291 Port number assigned to input

function selection 008.

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 38, “Input function

selection 008.”

* If a negative value is set, the function will be

assigned to input port No. 8.

* If “Program number specified for program start”

has been specified for input function selection

008, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

292 Port number assigned to input

function selection 009

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 39, “Input function

selection 009.”

* If a negative value is set, the function will be

assigned to input port No. 9.

* If “Program number specified for program start”

has been specified for input function selection

009, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

293 Port number assigned to input

function selection 010

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 40, “Input function

selection 010.”

* If a negative value is set, the function will be

assigned to input port No. 10.

* If “Program number specified for program start”

has been specified for input function selection

010, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

This manual is related to the following products: