Chapter 6 Parameter
6.1 I/O Parameter (All types)
302
I/O Parameter (All types)
No.
Parameter name
Default
value
(reference)
Input
range
Unit
Remarks
286 Port number assigned to input
function selection 003
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 33, “Input function
selection 003.”
* If a negative value is set, the function will be
assigned to input port No. 3.
287 Port number assigned to input
function selection 004
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 34, “Input function
selection 004.”
* If a negative value is set, the function will be
assigned to input port No. 4.
288 Port number assigned to input
function selection 005
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 35, “Input function
selection 005.”
* If a negative value is set, the function will be
assigned to input port No. 5.
289 Port number assigned to input
function selection 006
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 36, “Input function
selection 006.”
* If a negative value is set, the function will be
assigned to input port No. 6.
290 Port number assigned to input
function selection 007
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 37, “Input function
selection 007.”
* If a negative value is set, the function will be
assigned to input port No. 7.
* If “Program number specified for program start”
has been specified for input function selection
007, specify in this parameter an input port
number whose LSB contains the next higher
value to the LSB of the program number
specified for program start.
(Related information: I/O parameter No. 30,
“Input function selection 000”)
291 Port number assigned to input
function selection 008.
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 38, “Input function
selection 008.”
* If a negative value is set, the function will be
assigned to input port No. 8.
* If “Program number specified for program start”
has been specified for input function selection
008, specify in this parameter an input port
number whose LSB contains the next higher
value to the LSB of the program number
specified for program start.
292 Port number assigned to input
function selection 009
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 39, “Input function
selection 009.”
* If a negative value is set, the function will be
assigned to input port No. 9.
* If “Program number specified for program start”
has been specified for input function selection
009, specify in this parameter an input port
number whose LSB contains the next higher
value to the LSB of the program number
specified for program start.
293 Port number assigned to input
function selection 010
-1
-1 to 3999
Specify the port number to be assigned to the
function of I/O parameter No. 40, “Input function
selection 010.”
* If a negative value is set, the function will be
assigned to input port No. 10.
* If “Program number specified for program start”
has been specified for input function selection
010, specify in this parameter an input port
number whose LSB contains the next higher
value to the LSB of the program number
specified for program start.