Chapter 2 Wiring
2.2.7 PIO Circuit
95
(2) PNP Type
� 32 Input Points / 16 Output Points (Display of XSEL Mode Code: P1)
000
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
24V
common
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
Load
(Red-1)
(Orange-1)
(Yellow-1)
(Green-1)
(Blue-1)
(Purple-1)
(Gray-1)
(White-1)
(Black-1)
(Brown-2)
(Red-2)
(Orange-2)
(Yellow-2)
(Green-2)
(Blue-2)
(Purple-2)
(Gray-2)
(White-2)
(Black-2)
(Brown-3)
(Red-3)
(Orange-3)
(Yellow-3)
(Green-3)
(Blue-3)
(Purple-3)
(Gray-3)
(White-3)
(Black-3)
(Brown-4)
(Red-4)
(Orange-4)
(Brown-1)
(Yellow-4)
(Green-4)
(Blue-4)
(Purple-4)
(Gray-4)
(White-4)
(Black-4)
(Brown-5)
(Red-5)
(Orange-5)
(Yellow-5)
(Green-5)
(Blue-5)
(Purple-5)
(Gray-5)
(White-5)
50
(Black-5)
24V
common
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
1
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
0 V
24 V
I/O Board
Stated in () is a Wirer color of the supplied flat cable
Universal Input
Input function
is parameter
setup
Output function
is parameter
setup
�
The second (Slot No. 2) PIO board No., is decided with the I/O parameter No. 1 to 5 setting.
� Use the attached cable for the I/O connection.
Model : CB-X-PIO��� (��� indicates the cable length L. Example. 020 = 2m)
Cutting state
49
1
2
50
Socket (with strain relief) : XG4M-5030-T (Manufacturer: Omron))
Flat cable (50 conductors) : KFX-50 (S) (Manufacturer: Kaneko Cord)