Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

439

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

921 Extension motion control board

axis position number error

There is a mistake in the indication of the extension motion

control board axis position number.

922 Extension motion control board

parameter type indication error

An inappropriate parameter type was indicated in the

process of the extension motion control board parameter

reading/writing.

923 Extension motion control board

parameter number indication error

An inappropriate parameter number was indicated in the

process of the extension motion control board parameter

reading/writing.

924 Extension motion control board

number of parameters indication

error

An inappropriate number of parameters was indicated in the

process of the extension motion control board parameter

reading/writing.

925 Extension motion control board

parameter device number

indication error

An inappropriate parameter device number was indicated in

the process of the extension motion control board

parameter reading/writing.

926 Extension motion control board

flash ROM writing command type

error

An inappropriate command type was indicated while in the

process of the flash ROM writing to the extension motion

control board.

927 Extension motion control board

electronic cam table number

indication error

An inappropriate table number was indicated while in the

process of the electronic cam table data

reading/writing/clear.

928 Extension motion control board

electronic cam table section

definition data number indication

error

An inappropriate table section definition data number was

indicated while in the process of the electronic cam table

data reading/writing/clear.

929 Extension motion control board

electronic cam table section

definition number of data indication

error (Slave CPU detection)

An inappropriate table section definition number of data was

indicated while in the process of the electronic cam table

data reading/writing/clear.

92A Extension motion control board

electronic cam table displacement

data number indication error

An inappropriate table displacement data number was

indicated while in the process of the electronic cam table

data reading/writing/clear.

92B Extension motion control board

electronic cam table number of

displacement data indication error

(Slave CPU detection)

An inappropriate table number of displacement data was

indicated while in the process of the electronic cam table

data reading/writing/clear.

92C Extension motion control board

flash ROM writing command denial

error during axis in use

A writing command to the flash ROM was issued while in

the extension motion control board control axis operation.

Confirm that all the extension motion control board control

axes are stopped (not in use), and then conduct the writing

to the flash ROM again.

92D Extension motion control board

electronic cam table Writing

command denial error during axis

in use

A writing command to the electronic cam table data was

issued while in the extension motion control board control

axis operation.

Confirm that all the extension motion control board control

axes are stopped (not in use), and then conduct the writing

again.

92E Extension motion control board

number of electronic cam table s

indication error

An inappropriate number of electronic cam tables was

indicated while in the process of the electronic cam table

data reading/writing/clear.

92F Extension motion control board

nemory initializing data type

indication error

An inappropriate data type was indicated while in the

initializing process of the extension motion control board

memory.

930 Coordinate system number error

The coordinate system number is invalid.

* It is an error only for SCARA

M

es

sa

ge

le

ve

l e

rro

rs

931 Coordinate system type error

The coordinate system type is invalid.

* It is an error only for SCARA