4.2 Absolute Battery

4.2.1 Absolute Encoder Backup Type

The backup for the absolute position data is conducted by the battery.

The absolute encoder position data will be maintained even if the power to the robot is turned

OFF.

Batteries have a life, so it is recommended that you replace them at regular intervals.

Replacement Cycle (reference)

2 years

Replace the battery immediately if the absolute data backup battery voltage drop warning

(Error No. A23) is generated as a result of the battery voltage monitoring

(Note 1)

of the controller.

The period of grace after detecting the error till absolute data backup battery voltage error

(Error No. 914 and CA2) is approximately 10 days under the condition of continuously power

conducted in the ambient temperature at 20degC.

Once the Absolute Data Backup Battery Voltage Error (Error No. 914 and CA2) is detected,

the absolute reset operation becomes necessary.

Note1 You can cause a signal to be output to an output port when the absolute data backup

battery voltage drop warning is present.

Set I/O parameter No. 60 to “1,” and output port No. 314 will turn ON when the absolute

data backup battery voltage drop warning is present.

Absolute Encoder Battery Backup Type

Item

Specifications

Battery model

AB-5 (IAI model code)

Battery voltage

3.6V

Current capacity

2000mAH

2 years after start using

(in case being left without controller turned on)

Reference battery replacement

interval

(Note 2)

(Surrounding air temperature 40�C)

2 years after start using

(in case power conducted duration to controller is

50%)

Absolute Data Backup Battery

Voltage Drop Warning (Error No.

A23) Detecting voltage

3.0V to 3.2V

Absolute Data Backup Battery

Voltage Error (Error No. 914, and

CA2) Detecting voltage

2.3V to 2.7V

E

rr

or

d

et

ec

tio

n

Time before detecting Absolute

Data Backup Battery Voltage Error

(Error No. 914 and CA2) after

detecting Absolute Data Backup

Battery Voltage Drop Warning

(Error No. A23) (for reference only)

10 days of continuous operation, or 7 days without

power supply, at 20�C

10 days of continuous operation, or 2.5 days

without power supply, at 40�C

Minimum Data Retaining Voltage

Min. 2.7V (depends on encoder performance)

Time after detecting the absolute

battery voltage error (Error No. 914 and

CA2) till the data retaining failure (for

reference only)

If an error is detected in the absolute encoder, the

absolute reset is required with no exception.

Absolute data retaining time at battery

replacement

15 minutes

(It is the maximum allowable time.)

Note 2 Replace the battery regularly.