beautypg.com

IAI America XSEL-S User Manual

Page 126

background image

Chapter 2 Wiring

2.3.1 Wiring for Power Supply Circuit

118

[2] Single-phase power supply type

To X-SEL controllers, supply the following power supplies.

Power Supply Type

Specification

Remarks

Motor power supply

Single-phase

AC200V to 230V±10%

Control power supply Single-phase

AC200V to 230V±10%

I/O power supply

24V DC±10%

When mounting expansion I/O boards on

I/O slot

Brake power supply

24V DC±10%

For brake-equipped type

Shown below is an example for the power supply circuit wiring:

L

N

L

N

A.

B.

Single-phase

200V

+24V

0V

+24V

0V

Circuit

breaker

Leakage

Breaker

1) Noise

filter

3) Clamp Filter

2) Ring core

Motor

Power Supply

Control

Power Supply

Brake Power Input Connector

(option)

AC Power Supply

Input Connector

XSEL Controller

4) Clamp

Filter

Grounding resistance at 100Ω or less

24V DC

Power

Supply

Surge Protector

PWR BK

24V DC

Power

Supply

(Note1)

PIO Board

Power consumption and heat generation of a controller may differ depending on the

construction of such things as the driver board. Calculate the power consumption before

selecting a circuit breaker.

[Refer to Section 1.2]

Note 1 It is not required when there is no actuator with the brake.

Caution:

[S/SX/SXD type]

It is mandatory to mount a noise filter mentioned in 1) and a ring core mentioned in 2).

Without mounting these components, this controller may cause an error or unexpected

operation due to noise.

[R/RX/RXD type]

Apply these components in case the peripheral devices may get influenced by this

controller.

[Common]

Mount the clamp filter mentioned in 3) and 4) and surge protector mentioned in 5) if it is

necessary considering the noise environment and power source circumstance. It is

recommended to mount them even though it is not mandatory.

This manual is related to the following products: