Chapter 4

Absolute Reset and

Absolute Battery

4.1.1 For PC Software

186

4) By referring to the displayed movement direction for each axis, adjust the axes to the

initial posture. The posture differs depending on the movement direction. Click on “Display

the explanation of initial posture” to check the explanations. Make to work on with the

emergency stop activated when moving the axes with hand. Click on the “OK” button after

the work is finished.

[Initial posture]

Vertical Axis

For the position, put it apart from the coordinate 0mm (upward end) for 10mm or more.

Setting it at 10mm or less, Error No. B0D “Stopper Pressing Operation Start Position Error”

may occur at operation.

Rotation axis

There is no specific indication for the position of rotation shaft. It can be set at any position.

5) Click “Execution” button.

6) A Warning window shows up. Click “Yes”. The operation for the push type absolute reset

starts.