IAI America XSEL-S User Manual
Page 363

Chapter 6 Parameter
6.3.1 For XSEL-R/S
355
Axis-Specific Parameters (XSEL-R/S)
No.
Parameter name
Default value
(reference)
Input range
Unit
Remarks
192 (For expansion)
0
193 (For expansion)
0
194 ACMX+acceleration3
30
1 to 999
0.01G
Same as Each Axis Parameter No. 2
195 ACMX-acceleration3
30
1 to 999
0.01G
Same as Each Axis Parameter No. 3
196 ACMX+acceleration4
30
1 to 999
0.01G
Same as Each Axis Parameter No. 2
197 ACMX-acceleration4
30
1 to 999
0.01G
Same as Each Axis Parameter No. 3
198 (For expansion)
0
199 (For expansion)
0
200 (For expansion)
0
201
to
220
(For expansion)
0
221 Total Movement Count
Threshold
0
0 to
99999999
Alert function is invalid when
maintenance information alert function
setting is 0.
“231: Movement Times Threshold
Excess” is issued when maintenance
information “total movement times”
exceeds the setting in this parameter.
222 Total Operated Distance
Threshold
0
0 to
99999999
Alert function is invalid when
maintenance information alert function
setting is 0.
“232: Driving Distance Threshold
Excess” is issued when maintenance
information “total driving distance”
exceeds the setting in this parameter.
223
to
250
(For expansion)
0