background image

Chapter 6 Parameter

6.1 I/O Parameter (All types)

303

I/O Parameter (All types)

No.

Parameter name

Default

value

(reference)

Input

range

Unit

Remarks

294 Port number assigned to input

function selection 011

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 41, “Input function

selection 011.”

* If a negative value is set, the function will be

assigned to input port No. 11.

* If “Program number specified for program start”

has been specified for input function selection

011, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

295 Port number assigned to input

function selection 012

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 42, “Input function

selection 012.”

* If a negative value is set, the function will be

assigned to input port No. 12.

* If “Program number specified for program start”

has been specified for input function selection

012, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

296 Port number assigned to input

function selection 013

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 43, “Input function

selection 013.”

* If a negative value is set, the function will be

assigned to input port No. 13.

* If “Program number specified for program start”

has been specified for input function selection

013, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

297 Port number assigned to input

function selection 014

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 44, “Input function

selection 014.”

* If a negative value is set, the function will be

assigned to input port No. 14.

* If “Program number specified for program start”

has been specified for input function selection

014, specify in this parameter an input port

number whose LSB contains the next higher

value to the LSB of the program number

specified for program start.

(Related information: I/O parameter No. 30,

“Input function selection 000”)

298 Port number assigned to input

function selection 015

-1

-1 to 3999

Specify the port number to be assigned to the

function of I/O parameter No. 45, “Input function

selection 015.”

* If a negative value is set, the function will be

assigned to input port No. 15.

299 Port number assigned to output

function selection 300

0

0 to 6999

Specify the port number to be assigned to the

function of I/O parameter No. 46, “Output function

selection 300.”

* If 0 is set, the function will be assigned to output

port No. 300.

300 Port number assigned to output

function selection 301

0

0 to 6999

Specify the port number to be assigned to the

function of I/O parameter No. 47, “Output function

selection 301.”

* If 0 is set, the function will be assigned to output

port No. 301.

301 Port number assigned to output

function selection 302

0

0 to 6999

Specify the port number to be assigned to the

function of I/O parameter No. 48, “Output function

selection 302.”

* If 0 is set, the function will be assigned to output

port No. 302.

This manual is related to the following products: