IAI America XSEL-S User Manual
Page 429

Chapter 7
Troubleshooting
7.3 Error List (MAIN application)
421
In the panel window, the error numbers follow E in the display.
Error
No.
Error name
Description, action, etc.
49C SEL program source symbol
management domain ID error
SEL program is destroyed.
Initialize the SEL program.
49D Symbol definition table
management domain sum check
error
Symbol definition table is destroyed.
Initialize the symbol definition table.
49E Symbol definition table
management domain ID error
Symbol definition table is destroyed.
Initialize the symbol definition table.
49F Position data comment flash ROM
status error
Position data comment is destroyed.
Save the position data to flash ROM.
4A0 Position data comment
management domain sum check
error
Position data comment is destroyed.
Save the position data to flash ROM.
4A1 Position data comment
management domain ID error
Position data comment is destroyed.
Save the position data to flash ROM.
4A2 Position data comment sum check
error
Position data comment is destroyed.
Save the position data to flash ROM.
4A3 UBM management domain ID error User data retaining memory data is destroyed.
Initialize the user data retaining memory.
4A4 Maintenance information data
management domain sum check
error
Maintenance information data is destroyed.
Initialize the maintenance information data.�
4A5 Maintenance information data
management domain ID error�
Maintenance information data is destroyed.
Initialize the maintenance information data.�
O
pe
ra
tio
n-
ca
nc
el
la
tio
n
le
ve
l e
rro
rs
4A6 Maintenance information data sum
check error�
Maintenance information data is destroyed.
Initialize the maintenance information data.�