Chapter 2 Wiring

2.3.2 Wiring the Emergency Stop Circuit (System I/O )

120

2.3.2 Wiring the Emergency Stop Circuit (System I/O )

Item

R/RX/RXD Type

S/SX/SXD Type

Drive-source cutoff

circuit

Built-in

(Hard-wired configuration)

External circuit

[Refer to Section 8.1]

Conforming category

B

B, 1 to 4

Redundancy in safety

circuit

-

Achieved by an external circuit.

[Refer to Section 8.1]

Operation upon

emergency stop

Decelerate the actuator at the

emergency deceleration

(all-axis parameter No. 24) to a

stop, turn off the servo, and

then cut off the drive source.

Decelerate the actuator at the

emergency deceleration

(all-axis parameter No. 24) to a

stop and turn OFF the servo.

Recovery from

emergency stop

In the case that the input port 014 (or 007

(Note 1)

) has been set to

driving source cut-off cancellation input using the I/O parameter

No. 44, when the input port 014 (or 007

(Note 1)

) is turned ON, as

well as the recovery from emergency stop with the system I/O,

the recovery from emergency stop is performed.

If the input port is a general-purposed one, recovery can be

made by cancelling the emergency stop with the system I/O.

External output of

emergency stop status

Possible. (Set by I/O parameter No. 48.)

Note 1 Depends on setting in I/O Parameter No. 30

[Refer to 2.2.4 and 2.2.5 for the basic circuit configuration.]

[Refer to Section 8.1 for the compliance with Safety Categories.]