7.3 Error List (MAIN application)

459

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

D5A Fieldbus error (TOGGLE timeout) A TOGGLE timeout was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D5B Fieldbus error (Access-privilege

retry over)

An access-privilege retry over error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D5C Fieldbus error (Access-privilege

open error)

An access-privilege open error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D5D Fieldbus error (FBRS link error)

A FBRS link error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D5E Fieldbus error (Mailbox response) A mailbox response error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D5F Network I/F Module Class

Mismatch error�

The type of I/F module specified in I/O parameter No. 225

and the type of network module actually mounted do not

match.

Check the setting in I/O parameter No. 225 and the

combination of network I/F module actually mounted.�

D60 Expanded-SIO 2/4 CH insulation

power error

An Expanded-SIO insulation power error was detected.

D61 Expanded-SIO 1/3 CH insulation

power error

An Expanded-SIO insulation power error was detected.

D62 Expanded-SIO

baud-rate-generator clock

oscillation error

An Expanded-SIO clock oscillation error was detected.

D63 Expanded-SIO UART paging error An Expanded-SIO paging error was detected.
D64 Expanded-SIO assignment error The “board channel assignment number” or “expanded-I/O

slot assignment number” in I/O parameter Nos. 100, 102,

104, 106, 108 or 110 may be outside the input range or

duplicated, a serial communication expansion board may

not be installed in the specified slot, or a “communication

mode” other than RS232C may have been selected when

the “board channel assignment number” is other than “1” or

“2,” among other reasons.

D65 Power supply board mismatch

error

The inserted power supply board (standard / high capacity)

does not match with that set in the parameter.

D66 In-rush current control circuit error The in-rush current control relay is not working properly

even though the power is turned on.

D67 Motor/encoder configuration

information mismatch error

The “motor/encoder configuration information” (motor

identification number and encoder identification number) in

driver parameter No. 26 does not match the “motor/

encoder configuration information” (motor identification

number and encoder identification number) in encoder

parameter No. 11.

Check the parameter values, encoder cable connection,

etc.

Cold-st

art

lev

el

errors

D68 No remote-mode control support

board error

Hardware supporting remote-mode control is not installed,

although remote-mode control (AUTO/MANU) is specified

in I/O parameter No. 79.