beautypg.com

IAI America XSEL-S User Manual

Page 23

background image

15

12) I/O slots 1

······· [Refer to 2.3.4, For RC Gateway Function Fieldbus type, refer to the operation

manual provided separately.]

Either of PIO board (Option) or RC Gateway fieldbus board (Option) is to be inserted.

Mountable PIO Board

Name

XSEL Mode

Display

Number of Input

Number of Output

Polarity

N1

32

16

NPN

P1

32

16

PNP

N2

16

32

NPN

PIO

Board

P2

16

32

PNP

N3

48

48

NPN

Multipoint

I/O

Board

P3

48

48

PNP

RC

Gateway

Fieldbus

Board

DG

13) I/O slots 2 (Option) ······· [Refer to 2.3.4]

PIO board (Option) is inserted.

Mountable I/O Boards

Name

XSEL Mode

Display

Number of Input

Number of Output

Polarity

N1

32

16

NPN

P1

32

16

PNP

N2

16

32

NPN

PIO

Board

P2

16

32

PNP

N3

48

48

NPN

Multipoint

I/O

Board

P3

48

48

PNP

14) General-purpose RS232C Port Connectors 1 ······· [Refer to 2.3.11]

This is a port for connections with external RS232C devices.

15) General-purpose RS232C Port Connectors 2······· [Refer to 2.3.11]

This is a port for connections with external RS232C devices.�

This port is to be used when using RC Gateway SIO functions (standard).

[RC Gateway SIO functions (standard), refer to the operation manual provided separately.]

16) Field network Board (Option) Mounted Position 1

The EtherNet/IP or EtherCAT field network board (option) is to be mounted.

[Refer to the separate operation manual for field network.]

Mountable Field Network Boards

Name

XSEL Mode Display

EtherNet/IP Board

EP

EtherCAT Board

EC

This manual is related to the following products: