IAI America XSEL-S User Manual
Page 115

Chapter 2 Wiring
2.2.10 Extension I/O unit (Option)
107
� 16 Input Points / 32 Output Points (Display of XSEL Mode Code: N2)
Load
common
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
(Black-5)
50
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
0V
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
1
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
24V
common
(Red-1)
(Orange-1)
(Yellow-1)
(Green-1)
(Blue-1)
(Purple-1)
(Gray-1)
(White-1)
(Black-1)
(Brown-2)
(Red-2)
(Orange-2)
(Yellow-2)
(Green-2)
(Blue-2)
(Purple-2)
(Gray-2)
(White-2)
(Black-2)
(Brown-3)
(Red-3)
(Orange-3)
(Yellow-3)
(Green-3)
(Blue-3)
(Purple-3)
(Gray-3)
(White-3)
(Black-3)
(Brown-4)
(Red-4)
(Orange-4)
(Yellow-4)
(Green-4)
(Blue-4)
(Purple-4)
(Gray-4)
(White-4)
(Black-4)
(Brown-5)
(Red-5)
(Orange-5)
(Yellow-5)
(Green-5)
(Blue-5)
(Purple-5)
(Gray-5)
(White-5)
(Brown-1)
0 V
24 V
I/O Board
Universal output
Stated in () is a Wirer color of the supplied flat cable
Universal Input
PIO board No., is decided with the I/O parameter No. 707 to 714 setting.
� Use the attached cable for the I/O connection.
Model : CB-X-PIO��� (��� indicates the cable length L. Example. 020 = 2m)
�
Cutting state
49
1
2
50
Socket (with strain relief) : XG4M-5030-T (Manufacturer: Omron))
Flat cable (50 conductors) : KFX-50 (S) (Manufacturer: Kaneko Cord)