IAI America XSEL-S User Manual
Page 200

Chapter 4
Absolute Reset and
Absolute Battery
4.1.1 For PC Software
192
[Initial posture]
�
Arm1, Arm 2
Remove all the interferences of the peripheral devices, and set the posture to either of the
left arm system or the right arm system. It is set to right arm system when the unit is
shipped out.
Arm 2 =
Negative direction of coordinate
Arm 1 =
Positive direction of coordinate
Arm 1 =
Negative direction of coordinate
Arm 2 =
Positive direction of coordinate
For the position, put it apart from the stopper position for 10deg or more.
Setting it too close to the stopper, Error No. B0D “Push Stopper Operation Start Position
Error” may occur at operation.
�
Vertical Axis
For the position, put it apart from the coordinate 0mm (upward end) for 10mm or more.
Setting it at 10mm or less, Error No. B0D “Push Stopper Operation Start Position Error”
may occur at operation.
�
Rotation axis
There is no specific indication for the position of rotation shaft. It can be set at any position.
Initial posture of left arm system
Arm 1 = Positive direction of coordinate
Arm 2 = Negative direction of coordinate
Initial posture of right arm system (At the delivery)
Arm 1 = Negative direction of coordinate
Arm 2 = Positive direction of coordinate