Memory module: faulty file system [0x0068001c, Electronic nameplate: checksum error [0x0068001d, 0x0068001f – Lenze 9400 User Manual
Page 630: 0x0068001d, 0x0068001b, 0x0068001e, 0x0068001c, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
630
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Electronic nameplate: Communication error [0x0068001b]
Memory module: Faulty file system [0x0068001c]
Electronic nameplate: Checksum error [0x0068001d]
Firmware is incompatible with control card [0x0068001e]
Combination memory module/device not possible [0x0068001f]
Module ID (decimal)
Error ID (decimal)
104: Module identification
27
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Communication with the electronic nameplate is
interrupted, the data could not be read.
Check correct connection of the encoder cable.
Module ID (decimal)
Error ID (decimal)
104: Module identification
28
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Memory module is plugged in incorrectly or is defective.
• Plug in the memory module correctly.
• Exchange defective memory module.
Module ID (decimal)
Error ID (decimal)
104: Module identification
29
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The checksum of the electronic nameplate is defective.
Consultation with Lenze required.
Module ID (decimal)
Error ID (decimal)
104: Module identification
30
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Firmware is not compatible with the hardware.
Import the compatible firmware.
Module ID (decimal)
Error ID (decimal)
104: Module identification
31
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The memory module used is not supported by the
controller according to the license model.
Plug in supported module and switch the mains.
• The 9400 HighLine supports the MM220 (licence:
Motion Control HighLevel) and MM330 memory
modules (licence: Motion Control TopLevel).