Internal interfaces, Ls_manualjogopenloop" system block, 11 basic drive functions – Lenze 9400 User Manual
Page 414

11
Basic drive functions
11.5
Manual job, encoderless
414
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5.3
Internal interfaces | "LS_ManualJogOpenLoop" system block
In the function block editor, the system block LS_ManualJogOpenLoop makes the internal
interfaces to the basic function "Manual jog, encoderless" available.
Inputs
Note!
For the basic function "Manual jog, encoderless", the system block must be integrated
into the application task. When the FB editor is activated, the basic dialog boxes of the
corresponding technology application in »Engineer« change.
In the dialog box entitled "All basic functions", the "Manual jog, encoderless" button is
not shown until the project has been updated.
Identifier
DIS code | data type
Information/possible settings
MOL_bEnable
| BOOL
Requesting control via the basic function.
• Request is also possible via
TRUE If no other basic function is active, a changeover to the function state
"Manual jog, encoderless active" takes place and controlled
traversing of the drive can be carried out by means of the control
inputs
TRUEFALSE Actively controlled traversing is ended, i.e. a changeover from the
active function state "Manual jog, encoderless active" back to the
basic state "Controller not ready" takes place.
MOL_bJogPositive
| BOOL
Encoderless manual jogging in a positive/negative direction ( 413)
• Control is also possible via
.
MOL_bJogNegative
| BOOL
MOL_bActivateDataBit1
| BOOL
Selection and contents of the profile parameter set ( 412)
• Selection is also possible via
.
MOL_bActivateDataBit2
| BOOL
LS_ManualJogOpenLoop
MOL_bEnable
MOL_bJogNegative
MOL_bActivateDataBit1
MOL_bActivateDataBit2
MOL_bEnabled
MOL_bActive
MOL_bJogPositive
MOL_dnState
MOL_bDone
и
з
n
t