New application loaded [0x006a0003, Applicationtask: overflow [0x006a0004, Usertask: overflow [0x006a0005 – Lenze 9400 User Manual
Page 636: Idletask: overflow [0x006a0006, 0x006a0004, 0x006a0006, 0x006a0003, 0x006a0005, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
636
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
New application loaded [0x006a0003]
ApplicationTask: Overflow [0x006a0004]
UserTask: Overflow [0x006a0005]
IdleTask: Overflow [0x006a0006]
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Application has been changed by transmission from
Engineer or loading from the memory module.
- (Information only)
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
4
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Program runtime in Application task is too high.
Reduce program runtime by means of:
• Omitting functions (e.g. by reducing the number of
active FBs).
• Optimisation of functions to the calculating time.
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
5
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Program runtime in user task is too high.
Reduce program runtime by means of:
• Omitting functions (e.g. by reducing the number of
active FBs).
• Optimisation of functions to the calculating time.
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
6
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Program runtime in idle task is too high.
Reduce program runtime by means of:
• Omitting functions (e.g. by reducing the number of
active FBs).
• Optimisation of functions to the calculating time.