Page 625: Memory module has been removed [0x00680006, 0x00680006, 0x00680004, 0x00680005, 0x00680003, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
625
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Safety module is defect or missing [0x00680003]
MXI1: Module changed during operation [0x00680004]
MXI2: Module changed during operation [0x00680005]
Memory module has been removed [0x00680006]
Module ID (decimal)
Error ID (decimal)
104: Module identification
3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the safety module. Mains switching
• If the error occurs again: Switch off the controller,
remove safety module and plug in again, switch on
the controller again.
• If the error still occurs: Switch off controller and use a
different safety module.
Module ID (decimal)
Error ID (decimal)
104: Module identification
4
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
It was tried to plug an extension module into module slot
MXI1, which is not "Hot-plug"-able.
Plug in valid module and switch on mains.
• Through mains switching, the system accepts
modules without "hot plug" capability in the
following switch-on phase.
Module ID (decimal)
Error ID (decimal)
104: Module identification
5
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
It was tried to plug an extension module into module slot
MXI2, which is not "Hot-plug"-able.
Plug in valid module and switch on mains.
• Through mains switching, the system accepts
modules without "hot plug" capability in the
following switch-on phase.
Module ID (decimal)
Error ID (decimal)
104: Module identification
6
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
You have tried to remove or change the memory module
during operation.
Switch off the controller, plug in memory module and
switch on the controller again.
• If the error occurs again, the memory module is