1 requirements, 2 activation, Requirements – Lenze 9400 User Manual
Page 410: Activation, 11 basic drive functions

11
Basic drive functions
11.5
Manual job, encoderless
410
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5.2.1
Requirements
• Check and, if necessary, adjust the basic parameterisation:
• Optimisation of the current controller in the case of non-Lenze motors or motors that are not
included in the »Engineer« motor catalogue.
Optimising the current controller
• Parameterisation of motor monitoring corresponding to the existing motor with the
monitoring response "Fault".
• This function is especially important for monitoring the permissible r.m.s. current load on
motors at f
d
= 0 Hz.
• Activation of maximum current monitoring with the monitoring response "Fault" in the case
of non-Lenze motors or motor that are not included in the »Engineer« motor catalogue.
• Activation of motor temperature monitoring via PTC and/or KTY.
• The controller inhibit is active.
• The controller is in the "Controller not ready" state
• The basic function "Manual jog (OL)" is part of the active application; see
| "LS_ManualJogOpenLoop" system block
.
• No other basic function is active.
11.5.2.2
Activation
In order to request the control via the basic function, the MOL_bEnable enable input in the
application must be set to TRUE or
• If no other basic function is active, a changeover to the function state "Manual jog, encoderless
active" takes place and controlled traversing can be carried out by means of the control inputs
or by writing values into
• A successful changeover to the function state"Manual jog, encoderless active" is indicated by a
TRUE signal at the status output MOL_bEnabled.