1 actual value interpolation (principle), Actual value interpolation (principle), 8i/o terminals – Lenze 9400 User Manual
Page 286

8
I/O terminals
8.7
Touch probe detection
286
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.7.1
Actual value interpolation (principle)
If a touch probe is detected, the (remaining) time until the following task cycle is determined and
from this a time stamp is generated. On the basis of this time stamp, the L_SdTouchProbe FB can
then carry out a linear interpolation between the two actual position interpolation points; the
result is the precise actual position at the time of the physical touch probe event.
[8-3]
Actual value determination through linear interpolation (principle)
Actual position point 1
Actual position point 2
Residual time (dnTouchProbeTimeLag)
Data
processing
Application
Data
processing
Application
Data
processing
Application
Task cycle
Task cycle
Task cycle
t
Position
t
0
t
1
p
1
p
2
Touch probe received