C02960 | pos track choice, C02962 | number of pos data points, C02963 | pos data point choice – Lenze 9400 User Manual
Page 911: C02964 | change pos data point x, C02965 | change pos data point y, C02960, C02962, C02963, C02964, C02965

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
911
14
Parameter reference
14.2
Parameter list | C02960
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02960
C02962
C02963
C02964
C02965
Parameter | Name:
C02960 | Pos Track Choice
Data type: UNSIGNED_32
Index: 21615
d
= 546F
h
From software version V3.0
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02962 | Number of Pos Data Points
Data type: UNSIGNED_32
Index: 21613
d
= 546D
h
From software version V3.0
Changing cam data via parameterisation
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02963 | Pos Data Point Choice
Data type: UNSIGNED_32
Index: 21612
d
= 546C
h
From software version V3.0
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02964 | Change Pos Data Point X
Data type: INTEGER_32
Index: 21611
d
= 546B
h
From software version V3.0
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
-214748.3647
Unit
214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02965 | Change Pos Data Point Y
Data type: INTEGER_32
Index: 21610
d
= 546A
h
From software version V3.0
Changing cam data via parameterisation
Setting range
(min. value | unit | max. value)
Lenze setting
-214748.3647
Unit
214748.3647 0.0000 Unit
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000