C02772 | starting angle, C02773 | current, C02774 | acceleration time – Lenze 9400 User Manual
Page 892: C02772/1, C02773/1, C02774/1, C02773/x, To 71, C02772/2, C02772/3

14
Parameter reference
14.2
Parameter list | C02772
892
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02772
C02773
C02774
Parameter | Name:
C02772 | Starting angle
Data type: INTEGER_32
Index: 21803
d
= 552B
h
From software version V7.0
Basic function "
Setting range
(min. value | unit | max. value)
-180.0
°
180.0
Subcodes
Lenze setting
Info
C02772/1
0.0 °
Startangle 1
C02772/2
0.0 °
Startangle 2
C02772/3
0.0 °
Startangle 3
C02772/4
0.0 °
Startangle 4
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02773 | Current
Data type: INTEGER_32
Index: 21802
d
= 552A
h
From software version V7.0
100 % ½ I
max_device
Basic function "
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C02773/1
10.00 %
Current 1
C02773/2
10.00 %
Current 2
C02773/3
10.00 %
Current 3
C02773/4
10.00 %
Current 4
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C02774 | Acceleration time
Data type: INTEGER_32
Index: 21801
d
= 5529
h
From software version V7.0
Basic function "
Setting range
(min. value | unit | max. value)
0.001
s
2147483.647
Subcodes
Lenze setting
Info
C02774/1
1.000 s
Acceleration time 1
C02774/2
1.000 s
Acceleration time 2
C02774/3
1.000 s
Acceleration time 3
C02774/4
1.000 s
Acceleration time 4
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000