C01705 | energy: power input, C01902 | diagnostics x6: max. baud rate, C01903 | diagnostics x6: change baud rate – Lenze 9400 User Manual
Page 846: C01905 | diagnostics x6: curr. baud rate, 14 parameter reference

14
Parameter reference
14.2
Parameter list | C01705
846
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01705
C01902
C01903
C01905
Parameter | Name:
C01705 | Energy: Power input
Data type: UNSIGNED_32
Index: 22870
d
= 5956
h
From software version V9.0
Setting range
(min. value | unit | max. value)
0
W
4294967295
Subcodes
Lenze setting
Info
C01705/1
0 W
Energy m. 1: Power input
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01902 | Diagnostics X6: Max. baud rate
Data type: UNSIGNED_32
Index: 22673
d
= 5891
h
Maximum permissible baud rate of the standard device after determination of the baud rate at the diagnostic
interface X6
• Communication starts with the default standard device baud rate of 19200 baud.
Selection list
(Lenze setting printed in bold)
9600 9600 baud
19200 19.200 baud
38400 38.400 baud
57600 57.600 baud
115200 115.200 baud
230400 230.400 baud
375000 375.000 baud
750000 750.000 baud
1500000 1.500.000 baud
3000000 3.000.000 baud
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01903 | Diagnostics X6: Change baud rate
Data type: UNSIGNED_32
Index: 22672
d
= 5890
h
New determination of the baud rate at the diagnostic interface X6
Selection list
(Lenze setting printed in bold)
1 Set a higher baud rate
0 Ignore changes
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01905 | Diagnostics X6: Curr. baud rate
Data type: UNSIGNED_32
Index: 22670
d
= 588E
h
Current baud rate at diagnostics interface X6
Display range
(min. value | unit | max. value)
0
3000000
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1