C02656 | actual position (homing), C02657 | hm_dnstate, C02658 | hm_dnhomepos_p – Lenze 9400 User Manual
Page 877: C02659 | homing: dig. signals, C02659/1, C02659/2, C02659/3, C02659/4, C02658, C02659/5

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
877
14
Parameter reference
14.2
Parameter list | C02656
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02656
C02657
C02658
C02659
Parameter | Name:
C02656 | Actual position (homing)
Data type: INTEGER_32
Index: 21919
d
= 559F
h
Basic function "
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02657 | HM_dnState
Data type: INTEGER_32
Index: 21918
d
= 559E
h
Bit coded status of the basic function "
Display range
(min. value | unit | max. value)
-2147483648
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02658 | HM_dnHomePos_p
Data type: INTEGER_32
Index: 21917
d
= 559D
h
Display of the HM_dnHomePos_p input signal of the basic function "
".
Display range
(min. value | unit | max. value)
-214748.3647
214748.3647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02659 | Homing: Dig. signals
Data type: UNSIGNED_32
Index: 21916
d
= 559C
h
Display of the digital signals of the basic function "
".
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02659/1
HM_bEnable
C02659/2
HM_bActivateHoming
C02659/3
HM_bHomingMark
C02659/4
HM_bLoadHomePos
C02659/5
HM_bResetHomePos
C02659/6
HM_bEnabled
C02659/7
HM_bActive
C02659/8
HM_bDone
C02659/9
HM_bHomePosAvailable
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1