C00004 | service password, C00005 | application selection, C00006 | select motor control – Lenze 9400 User Manual
Page 733: C00007 | active application, C00005, C00007, C00006, Control" in, The o, R control type in

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
733
14
Parameter reference
14.2
Parameter list | C00004
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00004
C00005
C00006
C00007
Parameter | Name:
C00004 | Service password
Data type: UNSIGNED_32
Index: 24571
d
= 5FFB
h
Service code to unlock protected device commands (
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00005 | Application selection
Data type: INTEGER_32
Index: 24570
d
= 5FFA
h
Application selection
• Use the device command
="5" to activate the selected application.
Setting range
(min. value | unit | max. value)
Lenze setting
-1
16 0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00006 | Select motor control
Data type: UNSIGNED_32
Index: 24569
d
= 5FF9
h
Selection list
(Lenze setting printed in bold)
Info
1 SC: Servo control sync. motor
For synchronous motors with speed sensor
2 SC: Servo control async. motor
For asynchronous motors with speed sensor
4 SLVC: Sensorless vector control
From software version V3.0
6 VFCplus: V/f control open loop
From software version V3.0
7 VFCplus: V/f control closed loop
From software version V3.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00007 | Active application
Data type: INTEGER_32
Index: 24568
d
= 5FF8
h
Display range
(min. value | unit | max. value)
-2147483648
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1