C00180 | service code, C00181 | red. brake chopper threshold, C00182 | time for device search function – Lenze 9400 User Manual
Page 755: C00183 | device status, C00183, C00181, 0 v), 14 parameter reference

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
755
14
Parameter reference
14.2
Parameter list | C00180
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00180
C00181
C00182
C00183
Parameter | Name:
C00180 | Service code
Data type: VISIBLE_STRING
Index: 24395
d
= 5F4B
h
For Lenze service only
Read access Write access CINH PLC STOP No transfer
Character length: 192
Parameter | Name:
C00181 | Red. brake chopper threshold
Data type: UNSIGNED_32
Index: 24394
d
= 5F4A
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
V
100 0 V
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00182 | Time for device search function
Data type: UNSIGNED_16
Index: 24393
d
= 5F49
h
From software version V9.0
Setting range
(min. value | unit | max. value)
Lenze setting
0
6000 5
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00183 | Device status
Data type: UNSIGNED_32
Index: 24392
d
= 5F48
h
Display of the device state for diagnostic purposes
Selection list
(read only)
0 Operation
1 Operation/Warning active
2 Operation/warning locked act.
3 Operation/Quick stop active
4 Operation/Application stopped
10 Initialisation active
20 System fault active
90 Device is switched on
91 Device is switched on/QSP trouble
95 Device switched-on/energy saving
mode
101 Safe torque off active
102 Fault active
104 Trouble active
141 Drive ready to start --> C00142
151 Quick stop by trouble active
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1