C00078 | field contr. reset time, C00079 | motor - mutual inductance, C00080 | resolver - number of pole pairs – Lenze 9400 User Manual
Page 740: C00081 | rated motor power, C00082 | motor rotor resistance, C00083 | motor rotor time constant, C00079, C00082, C00081, C00083

14
Parameter reference
14.2
Parameter list | C00078
740
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00078
C00079
C00080
C00081
C00082
C00083
Parameter | Name:
C00078 | Field contr. reset time
Data type: UNSIGNED_32
Index: 24497
d
= 5FB1
h
Setting range
(min. value | unit | max. value)
Lenze setting
1.0
ms
6000.0 15.1 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00079 | Motor - mutual inductance
Data type: UNSIGNED_32
Index: 24496
d
= 5FB0
h
Display range
(min. value | unit | max. value)
0.0
mH
214748364.7
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00080 | Resolver - number of pole pairs
Data type: UNSIGNED_32
Index: 24495
d
= 5FAF
h
Adaptation of the resolver evaluation dynamics
Behaviour of the home position after mains switching
Setting range
(min. value | unit | max. value)
Lenze setting
1
10 1
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00081 | Rated motor power
Data type: UNSIGNED_32
Index: 24494
d
= 5FAE
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
kW
500.00 0.25 kW
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00082 | Motor rotor resistance
Data type: UNSIGNED_32
Index: 24493
d
= 5FAD
h
Display range
(min. value | unit | max. value)
0.0000
Ohm
214748.3647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C00083 | Motor rotor time constant
Data type: UNSIGNED_32
Index: 24492
d
= 5FAC
h
Display range
(min. value | unit | max. value)
0.00
ms
21474836.47
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100