1 "ls_ssiencoderx8" system block, Ed to the application via the, Ls_ssiencoderx8 – Lenze 9400 User Manual
Page 253: 6encoder evaluation

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
253
6
Encoder evaluation
6.3
Parameter setting
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3.8.1
"LS_SsiEncoderX8" system block
The LS_SsiEncoderX8 system block provides the SSI data words received to the application for
further processing in the function block editor.
Outputs
Gray-binary conversion
If an SSI encoder with Gray coding is used, a data conversion of Gray-to-binary code can be
connected in
individually for each output of the LS_SsiEncoderX8 SB, and thus for each
partword.
• In the Lenze setting "Binary coded" there is no conversion, i. e. an SSI encoder with binary coding
is expected.
Note!
• The LS_SsiEncoderX8 SB is only provided within controllers with a MM3xx or MM4xx
memory module.
• If a position is transmitted in the SSI data word, it is output in an unchanged manner
with regard to the position format by the LS_SsiEncoderX8 SB. For a use of the SSI
encoder as position encoder the position has to be converted into the 9400 format
afterwards by means of the L_EsEncoderConv FB.
Identifier
Data type
Value/meaning
SSI_dwDataword_1
DWORD
SSI partword 1
• In the Lenze setting the complete SSI data word received is shown at this output
without a conversion of the data format.
SSI_dwDataword_2
...
SSI_dwDataword_8
DWORD
SSI partwords 2 ... 8
• In the Lenze setting these outputs are deactivated.
Division of the SSI data word into partwords ( 254)
C00435/2
C00436/2
Start position
Length
C00435/1
C00436/1
C00435/3
C00436/3
C00435/4
C00436/4
C00435/5
C00436/5
C00435/6
C00436/6
C00435/7
C00436/7
C00435/8
C00436/8
Partword 1
Partword 2
Partword 3
Partword 4
Partword 5
Partword 6
Partword 7
Partword 8
C00437/2
Coding
C00437/1
C00437/3
C00437/4
C00437/5
C00437/6
C00437/7
C00437/8
C00424 Dataword length
C00423
Bitrate
C00422
Encoder type
C00421
Encoder voltage
SSI
dataword
LS_SsiEncoderX8
SSI_dwDataword_1
SSI_dwDataword_2
SSI_dwDataword_3
SSI_dwDataword_4
SSI_dwDataword_5
SSI_dwDataword_6
SSI_dwDataword_7
SSI_dwDataword_8
S
31