C01210 | counter: internal, C01212 | counter: power section overload, C01214 | internal clock – Lenze 9400 User Manual
Page 840: 14 parameter reference

14
Parameter reference
14.2
Parameter list | C01210
840
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01210
C01211
C01212
C01213
C01214
Parameter | Name:
C01210 | Counter: Internal
Data type: UNSIGNED_8
Index: 23365
d
= 5B45
h
From software version V8.0
Display range
(min. value | unit | max. value)
0
255
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01211 | Service code
Data type: UNSIGNED_32
Index: 23364
d
= 5B44
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01212 | Counter: Power section overload
Data type: UNSIGNED_16
Index: 23363
d
= 5B43
h
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01213 | Service code DataFlash
Data type: UNSIGNED_32
Index: 23362
d
= 5B42
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01214 | Internal clock
Data type: VISIBLE_STRING
Index: 23361
d
= 5B41
h
Display of the system time of the controller in the format "dd/mm/yyyy hh:mm:ss"
• Time and date are set via
.
If the MM440 memory module with real-time clock is plugged into the controller, the internal clock is adjusted to
the real-time clock every time the mains is switched on and every 24 hours at 0:00 o'clock.
• The daily adjustment is executed on a low-priority level. This is why it may take some seconds until the adjusted
time is displayed.
• During the adjustment process, status information of the real-time clock is also queried and entered into the
logbook.
Note:
If a memory module without real-time clock is plugged into the controller, the internal clock is initialised with
"01.01.1970 00:00:00" every time the mains is switched on.
Read access Write access CINH PLC-STOP No transfer
Scaling factor: 1
Character length: 21