System task 3: task overflow [0x0091000c, System task: task overflow [0x0091000d, Communication task: standstill > 3 s [0x0091000e – Lenze 9400 User Manual
Page 681: Cyclic task: standstill > 60 s [0x0091000f, 0x0091000e, 0x0091000f, 0x0091000c, 0x0091000d, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
681
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
System task 3: Task overflow [0x0091000c]
System task: Task overflow [0x0091000d]
Communication task: Standstill > 3 s [0x0091000e]
Cyclic task: Standstill > 60 s [0x0091000f]
Module ID (decimal)
Error ID (decimal)
145: Lenze runtime system
12
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
System overload.
Consultation with Lenze required.
Module ID (decimal)
Error ID (decimal)
145: Lenze runtime system
13
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
System overload.
Consultation with Lenze required.
Module ID (decimal)
Error ID (decimal)
145: Lenze runtime system
14
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Service data communication within the system (SDO
communication of all bus systems connected) has
caused an overload of service data processing. Due to
this, the monitoring interval of the processing task has
been violated. PDO communication is not affected by
this overload.
Reduce system load.
• Reduce the data and communication volume on the
buses. Processing will restart automatically when the
overload has been eliminated.
For systems frequently affected by this type of overload,
the error response can be changed to warning via code
in order to increase the drive availability.
Module ID (decimal)
Error ID (decimal)
145: Lenze runtime system
15
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
System overload or CRC check task crash.
Reduce system load.
• This is possible in the application or data transfer of
the communication interfaces.