4 cause & possible remedies, Logbook: overflow [0x00650000, Logbook: reset (read error) [0x00650001 – Lenze 9400 User Manual
Page 623: Logbook: reset (version error) [0x00650002, Apter, Cause & possible remedies, 0x00650000, 0x00650001, 0x00650002, 13 diagnostics & fault analysis

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
623
13
Diagnostics & fault analysis
13.7
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.7.4
Cause & possible remedies
This chapter contains all error messages of the controller operating system in numerical order of the
error numbers. The list provides detailed information on the response to the error message as well
as information on the cause & possible remedies.
Tip!
A list of all error messages of the controller operating system in alphabetical order can be
found in the previous chapter "
Logbook: Overflow [0x00650000]
Logbook: Reset (read error) [0x00650001]
Logbook: Reset (version error) [0x00650002]
Note!
Error message "Unknown error"
If the "Unknown error xxxx" error message is indicated in the logbook or in
reason for the missing plain text is that the error texts required have not been
downloaded to the controller during the application download.
• This, for instance, is the case if a device module plugged into the controller has not
been included in the Engineer project.
• Remedy: Include the device module, recompile and download the project.
Module ID (decimal)
Error ID (decimal)
101: Logbook module
0
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Too many events/faults have occurred in a very short
time. It was therefore not possible to list all of them in
the logbook.
Check whether application generates too many error
messages.
Module ID (decimal)
Error ID (decimal)
101: Logbook module
1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The logbook has been reset due to a read error..
- (is irreversible)
Module ID (decimal)
Error ID (decimal)
101: Logbook module
2
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The logbook has been reset due to a version conflict.
- (is irreversible)