C02523 | gearbox fac. denom.: pos. enc, C02524 | feed constant, C02525 | unit – Lenze 9400 User Manual
Page 850: C02526 | user-defined unit, C02527 | motor mounting direction, C02527, C02525, C02526, C02524, Relating

14
Parameter reference
14.2
Parameter list | C02523
850
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02523
C02524
C02525
C02526
C02527
Parameter | Name:
C02523 | Gearbox fac. denom.: Pos. enc.
Data type: INTEGER_32
Index: 22052
d
= 5624
h
Setting range
(min. value | unit | max. value)
Lenze setting
1
2147483647 1
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02524 | Feed constant
Data type: UNSIGNED_32
Index: 22051
d
= 5623
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.0001
Unit/rev.
214748.3647 360.0000 Unit/rev.
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02525 | Unit
Data type: UNSIGNED_32
Index: 22050
d
= 5622
h
Selection list
(Lenze setting printed in bold)
Info
0 User-defined
The text entered in
is displayed for the unit.
1 Incr.
2 μm
3 mm
4 m
5 inch
6 yard
7 °
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02526 | User-defined unit
Data type: VISIBLE_STRING
Index: 22049
d
= 5621
h
User-defined unit which is displayed when
="0" is selected.
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Character length: 8
Parameter | Name:
C02527 | Motor mounting direction
Data type: UNSIGNED_32
Index: 22048
d
= 5620
h
Selection list
(Lenze setting printed in bold)
0 Motor rotating CW
1 Motor rotating CCW
Read access Write access CINH PLC STOP No transfer