C02689 | position follower: dig. signals, C02692 | sf_dnmotoracc_x, C02693 | sf_dnspeedadd_s – Lenze 9400 User Manual
Page 882: C02694 | speed follower: % signals, C02689/1, C02689/2, C02694/1, C02693, C02692, C02694/2

14
Parameter reference
14.2
Parameter list | C02689
882
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02689
C02692
C02693
C02694
Parameter | Name:
C02689 | Position follower: Dig. signals
Data type: UNSIGNED_32
Index: 21886
d
= 557E
h
Display of the digital signals of the basic function "
Selection list
(read only)
0 FALSE
1 TRUE
Subcodes
Info
C02689/1
PF_bEnable
C02689/2
PF_bEnabled
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02692 | SF_dnMotorAcc_x
Data type: INTEGER_32
Index: 21883
d
= 557B
h
Display of the motor acceleration of the basic function "
Display range
(min. value | unit | max. value)
-7680000.0
7680000.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02693 | SF_dnSpeedAdd_s
Data type: INTEGER_32
Index: 21882
d
= 557A
h
Display of the additive speed setpoint of the basic function "
Display range
(min. value | unit | max. value)
-480000.0
rpm
480000.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02694 | Speed follower: % signals
Data type: INTEGER_32
Index: 21881
d
= 5579
h
Display of the scaled signals of the basic function "
Display range
(min. value | unit | max. value)
-200.00
%
200.00
Subcodes
Info
C02694/1
SF_dnSpeedSet_n
C02694/2
SF_dnTorqueAdd_n
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100