C00130 | rated power - brake resistor, C00131 - rated quantity of heat for brake res, C00133 | ref.: brake chopper utilisation – Lenze 9400 User Manual
Page 746: C00134 | minimum brake resistance, C00130, C00131, C00133, C00134, Ing in, C00173

14
Parameter reference
14.2
Parameter list | C00130
746
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00130
C00131
C00132
C00133
C00134
Parameter | Name:
C00130 | Rated power - brake resistor
Data type: INTEGER_32
Index: 24445
d
= 5F7D
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value)
Lenze setting
0
W
800000 5600 W
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00131 - Rated quantity of heat for brake res.
Data type: INTEGER_32
Index: 24444
d
= 5F7C
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value)
Lenze setting
0
kWs
100000 485 kWs
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00132 | Service code
Data type: INTEGER_32
Index: 24443
d
= 5F7B
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00133 | Ref.: Brake chopper utilisation
Data type: UNSIGNED_8
Index: 24442
d
= 5F7A
h
From software version V1.5
Selection list
(Lenze setting printed in bold)
Info
0 Minimum resistance (C00134)
1 Resistance in C00129
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00134 | Minimum brake resistance
Data type: INTEGER_32
Index: 24441
d
= 5F79
h
From software version V1.5
Display range
(min. value | unit | max. value)
0.0
Ohm
500.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10