2 parameter setting, 3 "ls_analogoutput" system block, Parameter setting – Lenze 9400 User Manual
Page 278: Ls_analogoutput" system block, 8i/o terminals

8
I/O terminals
8.3
Analog outputs
278
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.3.2
Parameter setting
Short overview of parameters for the analog outputs:
8.3.3
"LS_AnalogOutput" system block
In the function block editor the LS_AnalogOutput system block provides the interface to the analog
outputs.
Parameter
Info
Analog output 1: Gain
Analog output 2: Gain
Analog output 1: Offset
Analog output 2: Offset
Analog output 1: Output signal
Analog output 2: Output signal
Greyed out = display parameter
Input
Data type
Information/possible settings
AOUT1_dnOut_n
DINT
Analog output 1
• Scaling: ±2
30
≡ ±10 V
AOUT2_dnOut_n
DINT
Analog output 2
• Scaling: ±2
30
≡ ±10 V
LS_AnalogOutput
AOUT1_dnOut_n
AOUT2_dnOut_n
GA
AO1
AO2
X3
C02801/1
C02801/2
C02734/1 C02733/1
C02734/2 C02733/2