C00418 | activate resolver error compensation, C00420 | number of encoder increments, C00421 | encoder voltage – Lenze 9400 User Manual
Page 787: C00422 | encoder type, C00423 | ssi encoder: bit rate, C00422, C00420, C00421, C00418, C00423

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
787
14
Parameter reference
14.2
Parameter list | C00418
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00418
C00420
C00421
C00422
C00423
Parameter | Name:
C00418 | Activate resolver error compensation
Data type: UNSIGNED_8
Index: 24157
d
= 5E5D
h
From software version V7.0
Selection list
(Lenze setting printed in bold)
0 Deactivated
1 Activated
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00420 | Number of encoder increments
Data type: UNSIGNED_16
Index: 24155
d
= 5E5B
h
Setting range
(min. value | unit | max. value)
Lenze setting
1
16384 512
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00421 | Encoder voltage
Data type: UNSIGNED_16
Index: 24154
d
= 5E5A
h
Setting range
(min. value | unit | max. value)
Lenze setting
5.0
V
12.0 5.0 V
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00422 | Encoder type
Data type: UNSIGNED_16
Index: 24153
d
= 5E59
h
Selection list
(Lenze setting printed in bold)
Info
0 Incremental encoder (TTL signal)
1 Sin/cos encoder
2 Absolute value encoder (Hiperface)
3 Absolute value encoder (EnDat)
4 SSI encoder
From software version V5.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00423 | SSI encoder: Bit rate
Data type: UNSIGNED_32
Index: 24152
d
= 5E58
h
From software version V5.0
Setting range
(min. value | unit | max. value)
Lenze setting
150
kbps
1000 400 kbps
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1