I-1200, 9"can on board" system bus – Lenze 9400 User Manual
Page 350

9
"CAN on board" system bus
9.10
Implemented CANopen objects | I-1200
350
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I-1200
Identifier for the SDO server channel 1 (basic SDO channel).
• According to DS301 V4.02, the basic SDO channel can neither be changed nor deactivated.
[9-19] Data telegram assignment
Index:
I-1200
Name:
SDO1 server parameter
Subindex
Default setting
Display range (min. value | unit | max. value)
Access
Data type
0: Highest subindex supported
2
2
2 ro
U8
1: COB-ID client -> server (Rx)
Node ID + 0x600
0
4294967295 ro
U32
2: COB-ID server -> client (Tx)
Node ID + 0x580
0
4294967295 ro
U32
Subindex
Meaning
1
Specification of receive identifier
• For SDO server channel 1: node address (C00350) + 0x600
2
Specification of transmit identifier
• For SDO server channel 1: node address (C00350) + 0x580
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
Bit 31
Bit 30
Bit 29 ... bit 11
Bit 10 ... bit 0
0
0
Extended identifier*
11-bit identifier