Parameter | Name:
C00980 | VFC: Override point of field weakening
Data type: INTEGER_32
Index: 23595
d
= 5C2B
h
From software version V8.0
Offset of the override point of field weakening
• In the VFCplus operating mode the pull-out protection function or the maximally permissible current in the field
weakening range can be adapted.
Setting range
(min. value | unit | max. value)
Lenze setting
-500
Hz
500 0 Hz
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00985 | SLVC: Field current controller gain
Data type: UNSIGNED_32
Index: 23590
d
= 5C26
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
21474836.47 0.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00986 | SLVC: Cross current controller gain
Data type: UNSIGNED_32
Index: 23589
d
= 5C25
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
21474836.47 0.00
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00987 | SLVC: Gain - torque controller
Data type: UNSIGNED_32
Index: 23588
d
= 5C24
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.0000
Hz/A
1000.0000 0.5000 Hz/A
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C00988 | SLVC: Reset time - torque contr.
Data type: UNSIGNED_32
Index: 23587
d
= 5C23
h
From software version V3.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
ms
2000.00 10.00 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100