4 digital inputs, 1 terminal assignment/electrical data, 2 parameter setting – Lenze 9400 User Manual
Page 279: Digital inputs, Terminal assignment/electrical data, Parameter setting, Digital inputs ( 279), 8i/o terminals

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
279
8
I/O terminals
8.4
Digital inputs
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.4
Digital inputs
The controller is provided with eight freely configurable digital inputs.
• All digital inputs can be used for touch probe.
• The control input RFR of terminal strip X5 for controller enable is fixedly connected to the device
control.
8.4.1
Terminal assignment/electrical data
8.4.2
Parameter setting
Short overview of parameters for the digital inputs:
Terminal
Use
Electrical data
X5/DI1
X5/DI8
Digital input 1 ... 8
LOW level: 0 ... +5 V
HIGH level: +15 ... +30 V
Input current: 8 mA per input
(at 24 V)
External-voltage
protection:
Max. ±30 V
Conversion rate: 1 kHz
X5/RFR
Controller enable
See digital inputs
X5/GI
Reference potential (digital ground)
X5
GI
RFR
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
Parameter
Info
Digital input x - terminal pol.
Status: Digital inputs
Status word: Digital inputs
Digital inputs: Delay time
Greyed out = display parameter