2 parameter setting, 11 basic drive functions – Lenze 9400 User Manual
Page 389

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
389
11
Basic drive functions
11.3
Quick stop
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inputs
Outputs
11.3.2
Parameter setting
• Parameterisation dialog in »Engineer«: Tab Application parameter Dialog level Overview
All basic functions Quick stop
• Short overview of the parameters for quick stop:
Identifier
DIS code | data type
Information/possible settings
QSP_bActivate1
| BOOL
QSP_bActivate2
| BOOL
QSP_bActivate3
| BOOL
Activate quick stop
• The three inputs are linked via a logic OR gate.
TRUE If one of the three inputs is set to TRUE, a change-over to the "Quick
stop active" function state is effected and the drive is brought to
standstill within the deceleration time set for quick stop.
TRUEFALSE If all three inputs are reset to FALSE, a change-over to a setpoint-
generating basic function (e. g. "Speed follower") via the "Drive is
stopped" function state is effected.
QSP_bActivateDCBrake
| BOOL
From V3.0
Activate
• Only possible if V/f control or sensorless vector control is selected as motor
control type in
!
• This input has a higher priority than the three inputs QSP_bActivate1 ... 3.
TRUE A change-over to the "Quick stop active" function state is effected
and the drive is decelerated with the braking current set in
.
TRUEFALSE DC-injection braking is activated again.
• If flying restart is activated in
, a flying restart process is
automatically started to determine the current motor speed.
Identifier
DIS code | data type
Value/meaning
QSP_bActive
| BOOL
Status signal "Quick stop by application active"
• QSP_bActive is not set to TRUE if quick stop has been activated by another source,
e. g. via device command or as an error response ("Quick stop by trouble").
TRUE Quick stop has been requested via one of the three inputs
QSP_bActivate1 ... 3 and is active.
- or -
has been requested via QSP_bActivateDCBrake
and is active (only for motor control mode without encoder).
Parameter
Info
Decel. time - quick stop
Quick stop S-ramp time
Reference for quick stop deceleration time