C00350 | can node address, C00351 | can baud rate, C00352 | can slave/master – Lenze 9400 User Manual
Page 772: C00350, C00351, Or w, Ster in, C00352, Will, 14 parameter reference

14
Parameter reference
14.2
Parameter list | C00350
772
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00350
C00351
C00352
Parameter | Name:
C00350 | CAN node address
Data type: UNSIGNED_8
Index: 24225
d
= 5EA1
h
• A change in the node address will not be effective until a CAN Reset Node is performed.
• The basic server channel RX/TX is automatically provided by the node address (
; subcode 1).
• Overwriting the value deactivates a possibly existing node address selection entered by means of hardware.
Setting range
(min. value | unit | max. value)
Lenze setting
1
127 1
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00351 | CAN baud rate
Data type: UNSIGNED_8
Index: 24224
d
= 5EA0
h
• A change in the baud rate will not be effective until a CAN Reset Node is performed.
• Overwriting the value deactivates a possibly existing node address selection entered by means of hardware.
Selection list
(Lenze setting printed in bold)
0 500 kbps
1 250 kbps
2 125 kbps
3 50 kbps
4 1 Mbps
5 20 kbps
6 10 kbps
8 Reserved
9 Reserved
10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 800 kbps
15 Reserved
255 Automatic recognition
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00352 | CAN slave/master
Data type: UNSIGNED_8
Index: 24223
d
= 5E9F
h
The drive starts as CAN master after mains switching if a value of "1" has been entered and saved here.
Selection list
(Lenze setting printed in bold)
0 Slave
1 Master
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1