Cam data are corrupted [0x00b80014, Cam data restored [0x00b80015, 0x00b80014 – Lenze 9400 User Manual
Page 702: 0x00b80015, 0x00b80013, 0x00b80012, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
702
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Time-out torque feedforward control - brake [0x00b80012]
Cam data: Serial number MM does not match [0x00b80013]
Cam data are corrupted [0x00b80014]
Cam data restored [0x00b80015]
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
18
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
After 1 second the actual torque has not yet reached 90
% of the precontrolled setpoint torque for releasing the
brake.
Check settings for torque feedforward control.
• Possibly the maximum current (
) is not
sufficient for the required torque feedforward
control.
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
19
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The cam data are provided with an access protection of
level 3 (linkage to the memory module), and the serial
number contained in the cam data does not correspond
to the serial number of the memory module.
Check and, if required, correct the serial number entered
in »Cam Designer«. Afterwards redownload the cam
data.
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
20
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Checksum error during reading the file, or the password
was manipulated.
Redownload cam data.
Module ID (decimal)
Error ID (decimal)
184: Basic drive functions
21
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The last download of the cam data was faulty or has not
been completed successfully.
The previous cam data – if available – have been
downloaded from the backup file.
• Redownload cam data.
• Save cam data within the controller in the memory
module via device command
= "502: Save
cam data".