Parameter | Name:
C00120 | Mot. overload protection (I²xt)
Data type: UNSIGNED_32
Index: 24455
d
= 5F87
h
Threshold for I
2
x t disconnection
• Disconnection is carried out if the thermal motor load (
) is higher than the set threshold.
• A 100 % thermal motor load corresponds to a permanently flowing rated motor current
Note:
When the value is parameterised to 200 %, the monitoring mode of the motor overload protection is switched off!
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
200 105 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00121 | Warning threshold motor temperature
Data type: UNSIGNED_32
Index: 24454
d
= 5F86
h
Temperature threshold for motor temperature advance warning
• The response to reaching the threshold can be selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0
°C
150 120 °C
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00122 | Heatsink temp. warn. threshold
Data type: UNSIGNED_32
Index: 24453
d
= 5F85
h
Temperature threshold for heatsink temperature advance warning
• The response to reaching the threshold can be selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0
°C
85 85 °C
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00123 | Warning threshold device util.
Data type: UNSIGNED_32
Index: 24452
d
= 5F84
h
Adjustable threshold for I x t advance warning
• The advance warning is sent if the device utilisation (
) is higher than the set threshold.
• The response to reaching the threshold can be selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 90 %
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1