0x00a10002, 0x00a10003, 0x00a10004 – Lenze 9400 User Manual
Page 688: 0x00a10005, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
688
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CAN module (MXI1) RPDO3: Telegram not received or faulty [0x00a10002]
CAN module (MXI1) RPDO4: Telegram not received or faulty [0x00a10003]
CAN module (MXI1) RPDO5: Telegram not received or faulty [0x00a10004]
CAN module (MXI1) RPDO6: Telegram not received or faulty [0x00a10005]
Module ID (decimal)
Error ID (decimal)
161: CAN module in MXI1: CAN-PDO handler
2
Response (Lenze setting printed in bold)
Setting:
C13591/3
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
CANopen communication module in MXI1: CAN-IN 3
error
• Incorrect PDO telegram length.
• Transmission error.
• Time monitoring of the PDOs has tripped.
• Set correct telegram length for CAN master
(transmitter).
• Eliminate trouble in the environment (e. g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Module ID (decimal)
Error ID (decimal)
161: CAN module in MXI1: CAN-PDO handler
3
Response (Lenze setting printed in bold)
Setting:
C13591/4
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
CANopen communication module in MXI1: CAN-IN 4
error
• Incorrect PDO telegram length.
• Transmission error.
• Time monitoring of the PDOs has tripped.
• Set correct telegram length for CAN master
(transmitter).
• Eliminate trouble in the environment (e. g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Module ID (decimal)
Error ID (decimal)
161: CAN module in MXI1: CAN-PDO handler
4
Response (Lenze setting printed in bold)
Setting:
C13591/5
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
CANopen communication module in MXI1: CAN-IN 5
error
• Incorrect PDO telegram length.
• Transmission error.
• Time monitoring of the PDOs has tripped.
• Set correct telegram length for CAN master
(transmitter).
• Eliminate trouble in the environment (e. g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Module ID (decimal)
Error ID (decimal)
161: CAN module in MXI1: CAN-PDO handler
5
Response (Lenze setting printed in bold)
Setting:
C13591/6
( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
CANopen communication module in MXI1: CAN-IN 6
error
• Incorrect PDO telegram length.
• Transmission error.
• Time monitoring of the PDOs has tripped.
• Set correct telegram length for CAN master
(transmitter).
• Eliminate trouble in the environment (e. g. EMC).
• Select a different time monitoring or switch off time
monitoring.